FEATURE |
||||
|
115/230 VAC operation |
24 Vdc input |
* |
* |
|
|
Auto and manual control modes |
* |
* |
* |
* |
|
PID control (see feature description) |
* |
* |
* |
* |
|
Choice
of output modes:
|
* |
* |
* |
|
|
Non-isolated 0 to 10 V control output |
* |
* |
*(or 0-1mA meter output) |
|
|
Non-isolated 4 to 20 mA control output |
|
|
* |
* |
|
Non-isolated
0 to 10 V tension output |
* |
* |
|
|
|
Non-isolated
4 to 20 mA tension output |
|
|
|
|
|
Isolated 0 to 10 V control output (D version only) |
* (option) |
*(option) |
* |
* |
|
Isolated 4
to 20 mA control or tension output |
* (option) |
*(option) |
|
|
|
Remote Tension Amplifier capability |
* |
* |
* (option) |
* (option) |
|
Meter damping |
* (fixed) |
* |
*(adjustable) |
* (adjustable) |
|
Speed Follower Mode |
* (speed module) |
* (option) |
* (option) |
* (option) |
|
Diameter Compensated Speed Follower Mode |
* (speed module) |
* (option) |
|
|
|
Digital tension meter |
* (RCT interface) |
* |
* (option) |
* (option) |
|
E-stop |
* |
* |
* |
* |
| Soft start by tension (see feature description) |
* |
* |
* |
|
| Soft start by line speed (see feature description) |
* |
* |
* |
|
|
Extended Range |
* |
* |
* |
* |
|
Reverse output |
* |
* |
* |
* |
| Taper by 0 to 10 V input (see feature description) |
* (speed module) |
* (option) |
* (option) |
* (option) |
| Taper by diameter calculation (see feature description) |
* (speed module) |
* (option) |
* (option) |
|
| Tension limit LOW (see feature description) |
* |
* |
* (option) |
* |
| Tension limit HIGH (see feature description) |
* |
* |
* (option) |
|
|
Dual transducer input |
* (option) |
|
* (option) |
|
|
Dual calibration |
* |
|
* (option) |
|
|
Output meter |
|
*(digital display) |
* |
|
|
Remote auto set-pot |
* (option) |
*
|
* |
|
|
Remote tension-on/ tension-off |
* (option) |
* |
* |
|
|
Pneumatics |
separate
module |
separate
module |
integrated |
separate
module |
| Sample and Hold (see feature description) |
* (ratio 1:1) |
* (ratio 1:1) |
* |
|
|
* |
* |
* |
|
|
|
PLI tension
readout and setpoint |
* |
* |
|
|
|
Setup
uploads from RCT, PC or laptop PC |
* |
* |
|
|
|
Storage and recall of job setup parameters |
* |
* |
|
|
|
Ultrasonic
sensor - direct input |
* |
* |
* |
* |
|
Rider Roll
input |
* (Speed module) |
* |
* |
* |
|
Multiple
operator interface options |
* (handheld RCT, User
interface panel, PC or PLC) |
*(3 choices; no RCT) |
|
|
|
Push-button
setup and calibration |
* |
* |
|
|
|
Serial and Fieldbus communication capabilities |
* |
* |
|
|
(Speed Module) = Speed module is required only if signal from input into Control Module is not 0-10Vdc.