MTC DATA SHEET
Search for:

Test Your Substrate Quality with a Segmented Tension Roll
Quik-Cal: Push button calibration cuts setup time
TI17C amplifier output vs competition










SteadyWebTM MicroProcessor Controller

STANDARD FEATURES:

0-10 VOLT TENSION OUTPUT. Used to interface with computers of other control systems.

4-20mA TENSION OUTPUT - Used to interface with computers or other control systems.

DC DUAL CALIBRATION - Allows two calibration settings.

EMERGENCY STOP - Stops the tension controlled device quickly in an emergency situation. Upon a contact closure, controller goes to full output.

METER DAMPING - Eliminates rapid tension meter fluctuations and displays an average tension.

OUTPUT DIRECTION SELECTION - Select between normal and reverse output.

RATIO OUTPUT UP OR DOWN - Multiplies or divides the control output during flying splice operations.

REMOTE TENSION ON/OFF - Accommodates additional tension On/Off buttons in remote locations.

REMOTE TENSION SET POINT - Allows location of Auto tension set point pot outside the controller.

SAMPLE & HOLD - Used in flying splice applications upon a contact closure output is maintained at constant level until contact is opened.

SOFT START - Used on unwinds only, insures control output is low when machine starts. Actuated in 3 ways: Tension Level, Remote Contact Closure, and Speed Tachometer Signal.

SPEED FOLLOW - Uses a tach signal to maintain speed control in most intermediate applications.

STANDARD METER SCALES - 0-1, 5, 10, 25, 50, 100, 150, 250, 500, or 1000.

OPTIONS:

(230V) 230V Power Input

(24V) 24V Output (12V only)

(45V) 45V Output (12V only)

(180V) 180V Output (only with 230V power)

(CC) CHASSIS CONFIGURATION - No cover on enclosure and no operator devices.

(H6) REMOTE OPERATOR DEVICES - Enclosure with no cover, 6 foot harness (different lengths optional) to the legend plate with all operator devices.

(2E) REMOTE PNEUMATIC ASSEMBLY - A separate bracket housing the pneumatic components (12P only).

(DTI) DUAL TRANSDUCER INPUT - Accepts tension inputs from two different transducer sources.

(XR) EXTENDED RANGE - Makes the transducers twice as sensitive (transducer must also have XR option).

(8MM) METRIC AIR TUBING - 8mm (5/16") air input fitting (12P only).

(NMS) NON-STANDARD METER SCALE - Any non-standard meter with single scale or dual scale.

(RO) REVERSE OUTPUT - Increases output when tension exceeds set point. Used in intermediate applications where transducers are located after nip rolls.

(RTA) REMOTE TENSION AMPLIFIER (RTA) - Usually used with intrinsically safe amplifier such as the Dover TI7 which replaces the amplifier inside cover.

(TLS) TENSION LIMIT SWITCH - Relay actuates at a pre-set adjustable trip point. Can be used as a web break detector.

TAPER TENSION - Using DC tachs (TTDCT), pulse tachs (TTPT), roll followers (TTF), or external 0-10 VDC (TTR).

All option cards are available in kits and may be purchased separately. A kit includes mounting hardware and instructions.

SPECIFICATIONS

Power Input: 12P and 12D

12V

120/230 Volts 60/50Hz Single Phase @ 1 amp

120/230 Volts 60/50Hz Single Phase @ 5 amps

Output Control Range: 12P

12V

12D

0 to 75 psi (0 to 5,17 bar)

90 Volts DC, 45 VDC, 24 VDC, all @ 4 amps

0-10 Volts DC (isolated)

Tension Signal Output 0 to 10 VDC

4 to 20mA with 500 Ohm maximum load

Enclosure NEMA Type 1, Steel
Weight 26 lbs. (11.8 kg)
Air Connections: 12P In: 3/8" (9.5 mm) compression fitting for plastic tubing (5/16", 8 mm optional )

Out: 1/4" (6 mm) compression fitting for plastic tubing

Internal Air Filter: 12P 5 micron with 1/2 pint bowl and automatic drain
Transducer Power Supply 5 VDC, regulated, 10 VDC with extended range
Transducer Signal 500 millivolts DC per pair at rated load, 1 VDC with extended range
Mating Transducer Cable Connectors Amphenol MS3106A-10SL-3S
Zero Range 95% of transducer rating, minimum
Calibration Range 25:1
Temperature Range 32·F to 104·F (0·C to 40· C)
System Accuracy 1% to 3% typical
Tension Meter Heavy-duty, 2% accuracy with flame proof front or optional
Maximum Output Adjustment Range 0%-100%
Manual Output Range 0% to 100% of rated output
Output Multiplier Range (ratio) 1:10
Output Divider Range (ratio) 10:1
Tension Limit Switch relay contacts (option) N.O., N.C., rated at 1A 30V
Taper Tension Range (option) 0%-100% adjustable
Taper Tension Inputs

code TTDCT (using DC tachs)

code TTPT (using Pulse tachs)

code TTF (option-roll follower)

code TTR (option-external voltage)

Maximum of 3 VDC to 250 VDC switch selectable

300Hz to 40,000Hz at maximum line speed

10k Ohm minimum potentiometer

0-10 VDC core to full roll

Display/Keypad, Microprocessor Type N232/485, Function/value selects


Close Window To Return

Take the DFE Tension Control Survey

HOMEPRODUCTSDFE PROFILENEWS & EVENTSTECHNICAL INFORMATION
SALES LOCATIONSLINKSDOWNLOADSCONTACT USSURVEY
TRANSDUCERSPNEUMATIC BRAKESINDICATORSCONTROLLERSCUSTOM SOLUTIONS